Where our numbers come from
Last updated
We don't test products hands-on, and we never pretend to. We take published data, do the math in the open, and date every figure. Here is every source and every formula the site uses.
Sources
- Power stations: battery Wh, continuous and peak output, chemistry, weight and solar input from each brand's US product page. Price and stock are re-checked every day.
- Appliance energy use: the ENERGY STAR certified product datasets (refrigerators, TVs, room air conditioners), refreshed monthly.
- Running and starting watts: the wattage charts published by Honda, Champion, Generac and Cummins. Starting figures are shown as estimates.
- Medical devices: the maker's spec sheet, for example the ResMed AirSense 11.
- Electricity prices: the U.S. Energy Information Administration, average residential price by state, refreshed monthly.
- Plug-in solar laws: bill text and governors' announcements, tracked daily through LegiScan. A status changes only after a person has read the source.
Formulas
- average W = kWh per year ÷ 8.76
- hours on battery = Wh × 0.90 ÷ (average W ÷ 0.85 + idle W)
- generator running = Σ running W × 1.25
- generator starting = Σ running W + largest single surge
- $ per month = kWh per year ÷ 12 × ¢ per kWh ÷ 100
Assumptions, and why
We count 90% of the rated battery as usable, 85% inverter efficiency, and 15 W of inverter idle draw when the maker doesn't publish it. Each runtime page has sliders so you can change the last two.
What we won't do
Invent test results, star ratings or reviews; copy figures without a source; or let a commission rate decide a pick. If you find a wrong number, tell us.